Modulon (Modular UPS)
 

DPH Series 50-300/500/600 kVA

     
 
Modulon (Modular UPS) - DPH Series 50-300/500/600 kVA

The world's highest power density providing ultimate MW power protection with leading power performance and superior reliability

In this IT intensive world with heavy data traffic driven by cloud, 4G/5G and media streaming applications, IT managers are facing the challenges of increasing rack power density and limited data center space. Delta's innovative modular UPS technologies provide the answer to customers' demand for high power density, high power performance, and ultimate availability. The brand-new Delta Modulon DPH series UPS 50-300/500/600kVA achieves the industry's leading power density of 50kW per module, offering the smallest footprint and best space utilization. The Modulon DPH Series UPS is the ideal modular power protection for MW data centers to achieve total cost of ownership (TCO) optimization.

DPH series 50-500kVA UPS - Applications

Product available regions : EMEA, South America, SEA, India, China, Taiwan, Korea
Because product specifications vary slightly from region to region, please download your local leaflet or visit your local website for detailed product information.
 
     
 
  Excellent Power Performance
 
The industry's leading power density per module at 50kW in 3U space, and the smallest footprint for 500kVA in a single rack and 600kVA in two racks, to achieve the best utilization compared with its peers
High AC-AC efficiency up to 96.5% and ECO mode to 99% resulting in marked energy cost savings
Green mode featuring a load aggregation function optimizes system efficiency
 
  Ultimate Availability
 
Fully modularized design and hot-swappable key modules ensure Mean Time To Repair (MTTR) close to zero without downtime risk
Redundant components and dual CAN bus delivers highest system availability and avoids single point of failure
Modular UPS grows with your business by parallel expansion up to 8 units for 4.8MVA of total power capacity
 
  High Manageability
 
User-friendly 10” color touch screen enables easy local UPS management
Environment information such as security, water, fire, and temperature can be integrated into the UPS for easy monitoring via the LCD of the UPS
If the UPS is equipped with an external battery management system, the battery information can be integrated into the UPS and monitored via the LCD of the UPS
 
 
 
 
 
     
 
Specifications
 
 
 
 
Model
DPH 300 System / DPH 500 System / DPH 600 System
Power Rating
DPH 300 System
100,150,200,250,300 kVA
100,150,200,250,300 kW
Power Module Quantity : Up to 6 units
DPH 500 System
300,350,400,450,500 * kVA
300,350,400,450,450 kW
Power Module Quantity : Up to 9 units
DPH 600 System
500,550,600 kVA
500,550,600 kW
Power Module Quantity : Up to 12 units
Input
Nominal Voltage : 220/380V, 230/400V, 240/415V (3-phase, 4-wire + G)
Voltage Range : 176 ~ 276 Vac (full load)
Current Harmonic Distortion : < 3% **
Power Factor : > 0.99
Frequency Range : 40 ~ 70 Hz
Output
Voltage : 220/380V, 230/400V, 240/415V (3-phase, 4-wire + G)
Voltage Harmonic Distortion : ≤ 0.5% (linear load)
Voltage Regulation : ±1% (static)
Frequency : 50/60 ± 0.05 Hz
Overload Capability : ≤ 125% : 10 minutes; ≤ 150% : 1 minute; > 150%: 1 second
Display : 10” color touch screen
Interface
Standard :
RS232 x 1, Parallel port x 4, USB type A x 2, USB type B x 1, MODBUS x 1, Smart slot x 1, REPO x 1, EPO x 1, Input dry contact x 4, Output dry contact x 6, External battery temperature dry contact x 4, External switch/breaker status dry contact x 4, BMS (RJ45) x 1, Ethernet x 1
Optional :
Relay I/O card, Battery cabinet temperature sensor cable
Conformance
Safety : CE
Efficiency
AC-AC Mode : Up to 96.5%
ECO Mode : 99%
Battery
Nominal Voltage : ±240 Vdc
Charge Voltage : ±272V (adjustable from 204V to 312V)
Protection of Battery Deep Discharge : Yes
Environment
Operating Temperature : 0 ~ 40 ℃
Relative Humidity : 0 ~ 90% (non-condensing)
Audible Noise (at one meter)
DPH 300 System : < 75 dB
DPH 500 System : < 80 dB
DPH 600 System : < 85 dB
IP Protection : IP 20
Others
Parallel Redundancy and Expansion : Module and system redundancy, Maximum 8 units
Emergency Power Off : Remote (default) and local (optional)
Battery Start : Yes
Physical
Dimensions (W x D x H)
DPH 300 System : 600 x 1100 x 2000 mm
DPH 500 System : 600 x 1100 x 2000 mm
DPH 600 System : 1200 x 1100 x 2000 mm
Weight : UPS System (without power modules)
DPH 300 System : 311 kg
DPH 500 System : 317 kg
DPH 600 System : 605 kg
Weight : 50kW Power Module (optional)
36 kg
* The power module's power rating is adjustable to either 50kVA or 55.6kVA via touch panel.
** When input vTHD is less than 1%.

All specifications are subject to change without prior notice.
 
 
  Contact us
  Have a question or need any assistance that should be answered by a professional? Contact us, and let our staff help you.  
 
 
     
  Related Information
 
Partner Program
Videos
Tools
Services
Data Center Virtual Tour
 
 
 
 
 
Information
Privacy Policy Data Collection
Terms of use Contact us
 
Follow Us
© 2020 Delta Electronics, Inc. All Rights Reserved.